Analisis aliran didalam Cyclone Separator dengan Simulasi CFD menggunakan CFDSOF

From ccitonlinewiki
Revision as of 16:24, 30 November 2020 by Agus.nuryadi (talk | contribs) (1. Pengantar)
Jump to: navigation, search

Analisis aliran didalam Cyclone Separator dengan Simulasi CFD menggunakan CFDSOF Abstrak


1. Pengantar

Abi Rizky

Agus Nuryadi

The nomographs by Zanker can be used to make a preliminary estimate of the size of cyclone needed. The specialist manufacturers of hydrocyclone equipment should be consulted to determine the best arrangements and design for a particular application. Zanker’s method is outlined below and illustrated in the Example below and based on an empirical equation by Bradley (1960):

alt text

Where, d50 is the particle diameter for which the cyclone is 50 per cent efficient, Dc is diameter of the cyclone chamber, u is liquid viscosity, L is feed flow rate, pl = density of the liquid, and ps = density of the solid, g/cm3.

2. Objektif

3. Metodologi

4. Model Komputasi dan Simulasi

5. Hasil dan Pembahasan

5.1 Verifikasi 5.2 Validasi 5.3 Pembahasan

   5.3.1 ....


.... ...

6. Kesimpulan

7. Referensi