- 04:12, 12 May 2022 172.16.98.1 (talk) posted a new comment on Reutilization of Ex-Used ESDV for New Well Connection at Pertamina Hulu Mahakam (Model: LPS-13-360-CM28-FC Serial No.: A1502960011 Year: 2015 Tag No.: 3C-XXV510100 Order No.: R-15-AIOC-438216 no catalogue is available. habibian1354@yahoo.com)
- 16:53, 26 November 2019 172.16.98.1 (talk) posted a new comment on Reutilization of Ex-Used ESDV for New Well Connection at Pertamina Hulu Mahakam (Andaru sebagai tambahan bahwa spec design awal ESDV dapat mampu menahan 500 barg.)
- 13:48, 26 November 2019 Arkan.cesnanda (talk | contribs) posted a new comment on Reutilization of Ex-Used ESDV for New Well Connection at Pertamina Hulu Mahakam (Halo Aldo, PHM harus melakukan procurement ESDV dikarenakan terjadinya keterlambatan untuk meng-procure ESDV ketika terjadi transisi dari Total E&P menjadi PHM. Dikarenakan keterlambatan ini, maka terjadi shortage 17 unit ESDV untuk project well connec...)
- 13:37, 26 November 2019 Arkan.cesnanda (talk | contribs) posted a new comment on Reutilization of Ex-Used ESDV for New Well Connection at Pertamina Hulu Mahakam (Halo Andaru, untuk Ex-ESDV yang di gunakan kembali hanya diuji pada 65 barg karena mengikuti setting dari PSHH yang merupakan 65 barg. Pada kondisi 65 barg atau diatasnya maka PSHH akan menyebabkan ESDV tertutup. Namun nyatanya kondisi di lapangan dapa...)
- 13:24, 26 November 2019 Arkan.cesnanda (talk | contribs) posted a new comment on Reutilization of Ex-Used ESDV for New Well Connection at Pertamina Hulu Mahakam (Hello Nico, the settings of the PSHH and PSLL varies depending on the location of the well. In this case since the well is a remote well the PSHH is 65 barg and the PSLL is 3 barg. For adjacent well the settings of the PSHH is at 220 barg.)
- 23:24, 25 November 2019 Aldorenaldy (talk | contribs) posted a new comment on Reutilization of Ex-Used ESDV for New Well Connection at Pertamina Hulu Mahakam (Halo Arkan. Saya ingin bertanya. Mengapa PHM perlu melakukan procurement ESDV? Dan mengapa refurbish harus dilakukan pada ESDV yang lama? Aldo Renaldy - 1606881115)
- 15:03, 24 November 2019 Andaruwrtm (talk | contribs) posted a new comment on Reutilization of Ex-Used ESDV for New Well Connection at Pertamina Hulu Mahakam (Halo Arkan, ada yang ingin saya tanyakan. Mengapa Ex-ESDV yang ingin digunakan kembali hanya diuji dengan pressure test 65 barg saja? Apa yang terjadi jika Ex-ESDV diuji dengan pressure test sesuai dengan kondisi tekanan sesungguhnya pada flowline, yai...)
- 14:43, 22 November 2019 Nicoivander (talk | contribs) posted a new comment on Reutilization of Ex-Used ESDV for New Well Connection at Pertamina Hulu Mahakam (Hello, I'm curious for the PSLL, PSHH, and ESDV pressure settings. Does the pressure setting for those 3 components always kept same or changing depends on a certain conditions? Thank you 😁 Nico Ivander - 1606907562)