+ | Where: | ||
'''d50''' = the particle diameter for which the cyclone is 50 per cent efficient, '''Micron''' | '''d50''' = the particle diameter for which the cyclone is 50 per cent efficient, '''Micron''' | ||
+ | |||
'''Dc''' = diameter of the cyclone chamber, '''cm,''' | '''Dc''' = diameter of the cyclone chamber, '''cm,''' | ||
Revision as of 16:02, 25 November 2020
basic calculation cyclone
The nomographs by Zanker can be used to make a preliminary estimate of the size of cyclone needed. The specialist manufacturers of hydrocyclone equipment should be consulted to determine the best arrangements and design for a particular application. Zanker’s method is outlined below and illustrated in the Example below and based on an empirical equation by Bradley (1960):
Where:
d50 = the particle diameter for which the cyclone is 50 per cent efficient, Micron
Dc = diameter of the cyclone chamber, cm,
Determination of d50 from the desired particle separation